 Battery Safety
 
 
 
Fenghua batteries own excellent quality.
Test Procedure Test methods Test according as Batteries Fenghua batteries show
state Condition
Forced discharge 1.0CmA for 2.5hours UL1642 Discharge Fresh No explosion, No Fire
Overcharge 1.0CmA/12V SBA G1101 Charge Fresh No explosion, No Fire
Crush 13kN,Pressure UL1642,SBA G1101 Charge Fresh No explosion, No Fire
Heating 10min @ 150OC UL1642 Charge Fresh No explosion, No Fire
Impact 9.1kg/at 61cm UL1642 Charge Fresh No explosion, No Fire
External short circuit 1.3mm,2 Cu wire UL1642 Charge Fresh No explosion, No Fire
 
   